AGL50
Inverter space-vector per new plants an restructuring
Ideal solution for installations with low speed (from 4kW up to 7.5 kW)
AGL50 integrates "in a simple and intuitive way", the most advanced industry solutions, offer maximum flexibility for installation in "latest-generation systems" and in the modernization of existing ones.
Compact and complete devices that ensures fast start-up and installation and high performance control and comfort of travel of the elevator .
Choose Language:
| INPUT DATA | ||
| ULN – AC Input voltage | VAC | three-phase network 380 V (-15%) ... 480 V (+10%) |
| FLN – Input frequency | Hz | 50/60 Hz, ± 2% |
| Overvoltage threshold | VDC | 800 |
| Undervoltage threshold | ||
| @ 400 VAC | VDC | 380 |
| @ 480 VAC | VDC | 415 |
| Effective input current (@ In out) |
||
| @ 400 VAC | A | 11 … 19 |
| @ 480 VAC | A | 10 … 17 |
| OUTPUT DATA |
||
| IN – Rated output current |
||
| @ 400 VAC | A | 10.1 … 17.7 |
| @ 460 VAC | A | 8.6 … 14.9 |
| PN Motor | ||
| @ 400 VAC | kW | 4 … 75 |
| @ 460 VAC | HP | 5 … 10 |
| Overload | 170% *10 sec | |
| Maximum Switching frequency | kHz | 8 |
| Maximum output frequency | Hz | 500 |
| IGBT braking unit | Standard internal (with external resistor) braking torque 150% MAX | |
| Dimensions (W x H x D) | mm | 130 x 221 x 176,5 |
| Weight | kg | 3 |
| GENERAL SPECIFICATIONS | ||
| Type of motor | Asynchronous | |
| Motor overload control |
Yes | |
| Drive overload control |
Yes | |
| Braking resistor overload control |
No | |
| Serial communication |
RS485 with Modbus RTU protocol or Jbus | |
| Fieldbus |
No | |
| Protection degree |
IP20 | |
| Operating temperature |
-10°C … +50°C (up to 40°C without derating ) | |
| EMC compliance |
EN 12015, EN 12016 | |
| EMI Internal filter |
No | |
| Mains choke integrated |
No | |
| Standards |
EN 61800-1, IEC 143-1-1 | |
| Approvals |
CE | |
| Dimensions (Width x Height x Depth) | 130 x 221 x 176,5 mm | |
| Weight | 3 Kg | |









Feed RSS